Dr. BestPrice Logo
Monday - Friday: 9 am - 5 pm EST
Dental Code D6794: Retainer crown - titanium and titanium alloys

Dental Code D6794: Retainer crown - titanium and titanium alloys

Dental Code D6794 refers to the procedure known as a retainer crown made from titanium and titanium alloys. This dental code specifically denotes the use of these materials in the fabrication of a retainer crown, which is a type of dental restoration used to support and retain a dental prosthesis or a fixed dental restoration. 

Detailed Information about the Procedure and Steps

Dental Code D6794 indicates the use of titanium and titanium alloys in the construction of a retainer crown. Titanium is a biocompatible material known for its strength, durability, and corrosion resistance. It has been widely used in various medical and dental applications due to its excellent properties. When used for retainer crowns, titanium provides a reliable foundation for supporting dental prostheses or fixed restorations.

Initial Assessment and Treatment Planning

The process begins with an initial assessment by a dentist or prosthodontist to evaluate the patient's oral health and determine the need for a retainer crown. This assessment involves a thorough examination of the teeth, gums, and surrounding oral structures. If a retainer crown is deemed necessary, the dentist will discuss the treatment plan with the patient, explaining the benefits and potential risks associated with using a titanium or titanium alloy retainer crown. During the initial assessment, the dentist or prosthodontist may also consider factors such as the patient's bite alignment, occlusion, and esthetic requirements to ensure the retainer crown provides optimal function and appearance. Additionally, they may take X-rays or use advanced imaging techniques to assess the condition of the underlying tooth structure and surrounding bone, aiding in the accurate planning and execution of the retainer crown procedure.

Tooth Preparation

Once the treatment plan is established, tooth preparation is performed to create space for the retainer crown. This step involves removing a small amount of tooth structure to accommodate the crown accurately. The dentist will numb the area with local anesthesia to ensure a comfortable experience for the patient. After tooth preparation, an impression of the prepared tooth is taken using dental putty or digital scanning technology. After the tooth preparation, the dentist may place a temporary crown or protective covering over the prepared tooth to provide protection and maintain proper function until the final retainer crown is ready. The dental laboratory then utilizes the impression to create a highly precise and custom-fit retainer crown that perfectly matches the patient's tooth anatomy. Advanced digital technologies, such as computer-aided design and manufacturing (CAD/CAM), enable the fabrication of the retainer crown with exceptional accuracy and efficiency.

Fabrication of the Retainer Crown

The dental laboratory receives the impression and uses it to fabricate a custom retainer crown. The use of titanium or titanium alloys allows for precise and accurate construction of the crown. Titanium's biocompatibility ensures that the crown integrates well with the surrounding oral tissues, promoting long-term stability and durability. The dental technician uses computer-aided design and manufacturing (CAD/CAM) technology or traditional casting techniques to create the retainer crown.

Fitting and Bonding

Once the retainer crown is ready, the patient returns to the dental office for a fitting appointment. The dentist checks the fit, color, and aesthetics of the crown to ensure it matches the natural teeth. If any adjustments are necessary, they are made at this stage. Once the perfect fit is achieved, the retainer crown is bonded to the prepared tooth using dental cement or adhesive. The dentist ensures that the crown is securely placed and aligns with the patient's bite for proper function. During the fitting appointment, the dentist may also assess the patient's bite alignment and make any necessary adjustments to ensure the retainer crown's proper occlusion with the opposing teeth. Once the bonding process is complete, the dentist may use a curing light to activate the dental cement or adhesive, ensuring a strong and durable bond between the retainer crown and the prepared tooth. The patient is then provided with post-placement care instructions and scheduled for follow-up visits to monitor the long-term success of the retainer crown.

Post-Placement Care and Maintenance

After the retainer crown is bonded, the dentist provides instructions on post-placement care and maintenance. It is essential for patients to maintain good oral hygiene practices, including regular brushing, flossing, and dental check-ups. Routine dental visits allow the dentist to monitor the condition of the retainer crown and make any necessary adjustments or repairs to ensure its longevity.

Summary of Dental Code D6794

Dental Code D6794 indicates the use of titanium and titanium alloys in the fabrication of a retainer crown. This procedure involves the initial assessment and treatment planning, tooth preparation, fabrication of the crown using precise techniques, fitting and bonding of the crown, and post-placement care and maintenance. Titanium and its alloys offer excellent properties for retainer crowns, including strength, durability, and biocompatibility. By utilizing this dental code, dentists can provide patients with a reliable and long-lasting restoration option that supports dental prostheses or fixed restorations effectively. It is crucial for patients to follow proper oral hygiene practices and attend regular dental check-ups to ensure the continued success of the retainer crown.

Quality dental care meets your budget – discover the perfect match through Dr. BestPrice's price comparison.

D-Entry